packaged rooftop air condition

2018 New design Packaged Rooftop Air Condition

Model AC+W(R)F 035 - 1040
Brand AC+
Unit set
Min order 1
Supply ability 100 sets per month
Payment T/T
Port Chinese port
Certification CE
Place China
Packaging Export Standard
Send Inquiry

Packaged Roof Top Units (High ESP)

features

l 23 sizes Packaged Rooftop air condition available ranging from 9.9 kW to 298 kW cooling capacity.

l Cooling only and heat pump versions.

l Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.

l Direct expansion coils with condensate drain tray.

l High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.

l Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.

l Forward curve centrifugal fans for air treatment section and axial fans for condensation section.

l Front, side and underside air discharge of the treatment unit.

l High external pressure, long air supply distance.

l Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.

 

l Easy operation line controller:

¨   Cooling/Heating//Auto

¨   Error indication

¨   Timing On/Off

OPTIONAL

l Economizer with fresh, return air dampers with cowl for models from 060 to 280.

l Free cooling function for low ambient temperature.

l Hot gas bypass (where low-local situation occurs and where it is necessary avoid low suction pressure and “compressor cycling”).

l Low ambient control device for operation of outdoor units at ambient temperatures from less than20°Cdown to-10°C.

l Air pressure switch for indoor fan.

l High Static condenser fan option with sealed + drain condensing section.

l Optional water heating coil

l Metal or plastic mesh on condenser coil.

l Optional supply / return air configurations

l Upgraded evaporator fan motor drives.



TECHNICAL DATA

Model     AC+W(R)F

 

035

040

045

060

070

080

085

090

Cooling

 

 

 

 

 

 

 

 

 

Cooling capacity *

kW

9.9

12

15.5

17.5

20.3

24

25.5

28.5

Total power input *

kW

3.91

4.1

5.3

5.5

6.67

8.8

8.98

9.86

Heating

 

 

 

 

 

 

 

 

 

Heating capacity *

kW

11.9

13.2

16.6

18.4

22.7

26.5

30.0

35.6

Total power input *

kW

3.72

3.8

4.8

5.1

6.6

8.2

8.45

9.99

Compressors

 

 

 

 

 

 

 

 

 

Qty/refrigerant circuit

Nr.

1/1

1/1

1/1

1/1

1/1

1/1

2/1

2/1

Energy control steps

step

1

1

1

1

1

1

3

2

Air treatment section

 

 

 

 

 

 

 

 

 

Centrifugal fans number

Nr.

1

1

1

1

1

1

1

1

Drive type

/

Direct

Direct

Direct

Direct

Direct

Direct

Belt

Belt

Air flow

m3/h

1800

2100

2600

3400

3600

4100

4500

5400

External static pressure

Pa

100

100

100

100

200

200

250

200

Motor power

kW

0.32

0.32

0.37

0.45

0.93

1.1

1.34

1.35

Condensation section

 

 

 

 

 

 

 

 

 

Axial fans number

Nr.

1

1

1

1

1

1

1

1

Air flow

m3/h

3961

4600

7800

7800

8641

9000

9434

9434

Motor power

kW

0.17

0.25

0.37

0.37

0.41

0.55

0.55

0.55

Power supply

/

380V/3N/50Hz

Net weight

kg

240

240

260

290

402

420

461

461

Sound pressure level **

dB(A)

67

67

67

68

71

71

70

70


 

Model     W(R)F

 

095

100

120

130

150

170

200

240

Cooling

 

 

 

 

 

 

 

 

 

Cooling capacity *

kW

30.3

32.4

35.6

41.6

47.2

53.2

63.3

71.4

Total power input *

kW

11.3

10.44

12.3

13.7

17

19.5

22.8

26.7

Heating

 

 

 

 

 

 

 

 

 

Heating capacity *

kW

33.3

37.6

40.5

48.2

50.2

56.4

67

75.6

Total power input *

kW

10.4

10.65

11.3

13.14

15.6

18

21

24.8

Compressors

 

 

 

 

 

 

 

 

 

Qty/refrigerant circuit

Nr.

2/2

2/1

2/2

2/2

2/1

2/1

2/1

2/1

Energy control steps

step

2

2

2

3

2

2

2

2

Air treatment section

 

 

 

 

 

 

 

 

 

Centrifugal fans number

Nr.

1

1

1

1

1

1

1

1

Drive type

/

Belt

Belt

Belt

Belt

Belt

Belt

Belt

Belt

Air flow

m3/h

5200

5200

6300

7020

7660

8500

10900

12500

External static pressure

Pa

200

250

260

250

250

250

300

300

Motor power

kW

1.5

1.5

2.2

2.73

3

3

4

4

Condensation section

 

 

 

 

 

 

 

 

 

Axial fans number

Nr.

1

1

1

1

1

1

1

1

Air flow

m3/h

12600

12600

12600

15600

16500

21000

21000

27000

Motor power

kW

0.75

0.75

0.75

0.9

1.1

1.5

1.5

2.2

Power supply

/

380V/3N/50Hz

Net weight

kg

480

505

650

725

750

770

880

960

Sound pressure level **

dB(A)

72

72

72

72

75

75

75

75

 

* Performance values refer to the following conditions:

Cooling: room air temperature27.0°CDB RH 50%, ambient air temperature35°C;

Heating: room air temperature21.0°CDB, ambient air temperature7°CDB /6°CWB.     

** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of1.5mhigh fan speed.


TECHNICAL DATA

Model     W(R)F

 

260

280

360

480

600

730

1040

Cooling

 

 

 

 

 

 

 

 

Cooling capacity *

kW

90

105.1

120

149

180

210

298

Total power input *

kW

32.9

39.7

45.10

55.1

69.9

83

106.7

Heating

 

 

 

 

 

 

 

 

Heating capacity *

kW

96.2

113.2

128.3

159.2

192.5

226

318

Total power input *

kW

30.4

36.7

41.70

51.5

64.8

77

100

Compressors

 

 

 

 

 

 

 

 

Qty/refrigerant circuit

Nr.

3/3

3/3

4/4

2/2

6/6

6/6

4/4

Energy control steps

step

3

3

4

2

6

6

4

Air treatment section

 

 

 

 

 

 

 

 

Centrifugal fans number

Nr.

1

1

1

1

1

1

1

Drive type

/

Belt

Belt

Belt

Belt

Belt

Belt

Belt

Air flow

m3/h

16000

19500

21000

26000

32000

38000

54000

External static pressure

Pa

300

300

400

450

500

500

460

Motor power

kW

5.5

5.5

7.5

11

15

15

18.5

Condensation section

 

 

 

 

 

 

 

 

Axial fans number

Nr.

2

2

2

2

4

4

4

Air flow

m3/h

33000

42000

42000

54000

66000

84000

108000

Motor power

kW

2x1.1

2x1.5

2x1.5

2x2.2

4x1.1

4x1.5

4x2.2

Power supply

/

380V/3N/50Hz

Net weight

kg

1160

1350

1710

1850

2180

2430

2860

Sound pressure level **

dB(A)

75

75

79

79

80

80

82

* Performance values refer to the following conditions:  

Cooling: room air temperature27.0°CDB RH 50%, ambient air temperature35°C;  

Heating: room air temperature21.0°CDB, ambient air temperature7°CDB /6°CWB 

** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of1.5mhigh fan speed.

 



Packaged Rooftop Air Condition 

Model: AC+W(R)F 035 ÷ 1040

Refrigerant : R410A

Cooling capacity range:9.9 - 298 kW

Heating capacity range:12.9 - 318kw